The method has also been developed for dissolution of antidiabetic drugs. Initially the solubility was determined in different dissolution media. The dissolution study of drugs was performed in 7.8 pH phosphate buffer in which these two drugs shows highest solubility. The dissolution was performed in pH 2.0 medium. The dissolution study was performed using Paddle with sinkers at 75 rpm. The amount of drugs were estimated.