The design, construction and optimization of a low power-high temperature heated ceramic sensor to detect leaking of halogen gases in refrigeration systems are presented. The manufacturing process was done with microelectronic assembly and the Low Temperature Co-fired Ceramic (LTCC) technology. Four basic sensor materials were fabricated and tested (Lithium Silicate, Sodium Silicate, Potassium Silicate, and Calcium Silicate). The evaluation of the sensor material, sensor size, operating temperature, bias voltage, electrodes size, firing temperature, gas flow, and sensor life was done. All…mehr

Produktbeschreibung
The design, construction and optimization of a low
power-high temperature heated ceramic sensor to
detect leaking of halogen gases in refrigeration
systems are presented. The manufacturing process was
done with microelectronic assembly and the Low
Temperature Co-fired Ceramic (LTCC) technology. Four
basic sensor materials were fabricated and tested
(Lithium Silicate, Sodium Silicate, Potassium
Silicate, and Calcium Silicate). The evaluation of
the sensor material, sensor size, operating
temperature, bias voltage, electrodes size, firing
temperature, gas flow, and sensor life was done. All
sensors respond to the gas showing stability and
reproducibility. The sensors were analyzed, modeled
and the response to the gas was divided in surface
diffusion and bulk diffusion within the sensor. The
theoretical results obtained by the modeling of the
sensor were in agreement with the experimental
values.
Autorenporträt
Dr. Mary Cristina Ruales Ortega currently works as an Assistant
Professor in the Mechanical Engineering Department at
Universidad del Turabo in Puerto Rico. Dr. Ruales received a
BSME from Universidad del Valle in Colombia, a MSME from the
University of Puerto Rico and a Ph.D. from Florida International
University in 2007.