Since its commercial introduction in 2004, UHPLC (Ultra-High Performance Liquid Chromatography) has begun to replace conventional HPLC in academia and industry and interest in this technique continues to grow. Both the increases in speed and resolution make this an attractive method; particularly to the life sciences and more than 1500 papers have been written on this strongly-evolving topic to date. This book provides a solid background on how to work with UHPLC and its application to the life sciences. The first part of the book covers the basics of this approach and the specifics of a UHPLC…mehr
Since its commercial introduction in 2004, UHPLC (Ultra-High Performance Liquid Chromatography) has begun to replace conventional HPLC in academia and industry and interest in this technique continues to grow. Both the increases in speed and resolution make this an attractive method; particularly to the life sciences and more than 1500 papers have been written on this strongly-evolving topic to date. This book provides a solid background on how to work with UHPLC and its application to the life sciences. The first part of the book covers the basics of this approach and the specifics of a UHPLC system, providing the reader with a solid background to working properly with such a system. The second part examines the application of UHPLC to the life sciences, with a focus on drug analysis strategies. UHPLC-MS, a key technique in pharmaceutical and toxicological analyses, is also examined in detail. The editors (Davy Guillarme and Jean-Luc Veuthey) were some of the earliest adopters of UHPLC and have published and lectured extensively on this topic. Between them they have brought together an excellent team of contributors from Europe and the United States, presenting a wealth of expertise and knowledge. This book is an essential handbook for anyone wishing to adopt an UHPLC system in either an academic or industrial setting and will benefit postgraduate students and experienced workers alike.Hinweis: Dieser Artikel kann nur an eine deutsche Lieferadresse ausgeliefert werden.
Davy Guillarme gained his PhD in analytical chemistry from the University of Lyon (France) in 2004. He is now lecturer at the School of Pharmaceutical Sciences, University of Geneva (Switzerland). He is working mainly on the development of new approaches to perform ultra-fast and high resolution separations in liquid chromatography. He is also interested in the coupling of these strategies with alternative detection modes, particularly mass spectrometry. Jean-Luc Veuthey obtained his PhD in analytical chemistry from the University of Geneva (Switzerland) in 1987. He is now full professor at the School of Pharmaceutical Sciences, University of Geneva (Switzerland). His interests include the development of LC and CE hyphenated to several detection modes for the analysis of drugs and metabolites. Sample preparation and validation of the procedures are also particularly studied in his laboratory.
Inhaltsangabe
1.1. Trends in HPLC 1.2. Comparison of Chromatographic Techniques and Supports 1.3. Constructing Kinetic Plots 1.4. History of the Kinetic Plot Method 1.5 Unification of the Isocratic and Gradient Kinetic Plot Method 1.6. Relation between the Kinetic Performance under Isocratic and Gradient Elution Conditions 1.7. Influence of the Test Conditions on the Obtained Kinetic-Performance Limit Curve 1.8. Some Reflections on Recent Trends in Liquid Chromatography using the Kinetic Plot Method 1.9. Conclusions Acknowledgements References 2.1 UHPLC Instrumentation 2.2 UHPLC Columns 3.1 Introduction 3.2 Qualitative Transfer from HPLC to UHPLC 3.3 Normative Context for the HPLC to UHPLC Transfer 3.4 Validation of UHPLC Methods and Equivalence of the HPLC-UHPLC Methods 3.5 Conclusions 3.6 References 4.1 Introduction 4.2 High throughput and high resolution in HT-UHPLC 4.3 Limitations of HTLC and HT-UHPLC 4.4 Advantage of high temperature in life science analysis 4.5 HT-UHPLC in comprehensive on-line two-dimensional liquid chromatography (LC x LC) 4.6 Conclusion 5. Comparison of the performance of totally porous and core-shell particles 5.1. Introduction 5.2. Column performance 5.3. Possibilities of recent core-shell technology 5.4. Particle size distribution and roughness of core-shell particles 5.5. Loading capacity of core-shell particles 5.6. Limited efficiency when core-shell particles packed in narrow-bore columns 5.7. Extra column effects, contribution to band broadening 5.8. Performance of core-shell and totally porous particles in isocratic elution mode 5.9. Performance of core-shell and totally porous particles in gradient elution mode 5.10. Conclusion 6.1 Introduction 6.2 Analytical Conditions for performing HILIC. 6.3 Applications of HILIC in UHPLC. 6.4 References. 7.1 Introduction 7.2 Selection of ionization techniques 7.3 Overview of mass analyzers and their main features 7.4 New developments in mass spectrometry applicable in UHPLC/MS 7.5 Conclusions 8.1 Introduction 8.2 Solubility 8.3 Ionization 8.4 Lipophilicity 8.5 Permeability 8.6 Conclusion 8.7 References 9.1 Introduction 9.2 UHPLC in Bioanalysis 9.3 Sample preparation for UHPLC in bioanalysis 9.4 Conclusions 10.1 Introduction 10.2 GC-MS Analyses 10.3 LC-MS(/MS) Analyses 10.4 Application of UHPLC-MS(/MS) for Drug Testing in Sports 10.5 Conclusion References 11.1 Introduction 11.2 Use of UHPLC for the Analysis of Seized Drugs 12.1. Pharmaceuticals as environmental contaminants 12.2. Analysis of pharmaceuticals in environmental samples 12.3. Occurrence of pharmaceuticals in environmental and wastewater samples 12.4. Conclusions Acknowledgements References 13.1 Introduction 13.2 Multiple Facets of UHPLC in NP research 13.3 Fast Targeted Analysis 13.4 Fast Non-Targeted Analysis, Fingerprinting, and Metabolomics 13.5 High-Resolution Profiling and Metabolite ID 13.6 Conclusion Acknowledgments References 14.1. Introduction 14.2. Pre-analysis Considerations: Protocol Design, Sample Collection, Storage and Preparation 14.3. Sample Preparation for Serum and/Plasma 14.4. Collection and Storage of Urine Samples 14.5. UHPLC-MS-Based Metabolite Profiling 14.6. Applications of UHPLC-MS to Human Metabolic Profiling Studies 14.7 Current Challenges for UHPLC-MS in Global metabolic profiling Studies 14.8. Conclusions
1.1. Trends in HPLC 1.2. Comparison of Chromatographic Techniques and Supports 1.3. Constructing Kinetic Plots 1.4. History of the Kinetic Plot Method 1.5 Unification of the Isocratic and Gradient Kinetic Plot Method 1.6. Relation between the Kinetic Performance under Isocratic and Gradient Elution Conditions 1.7. Influence of the Test Conditions on the Obtained Kinetic-Performance Limit Curve 1.8. Some Reflections on Recent Trends in Liquid Chromatography using the Kinetic Plot Method 1.9. Conclusions Acknowledgements References 2.1 UHPLC Instrumentation 2.2 UHPLC Columns 3.1 Introduction 3.2 Qualitative Transfer from HPLC to UHPLC 3.3 Normative Context for the HPLC to UHPLC Transfer 3.4 Validation of UHPLC Methods and Equivalence of the HPLC-UHPLC Methods 3.5 Conclusions 3.6 References 4.1 Introduction 4.2 High throughput and high resolution in HT-UHPLC 4.3 Limitations of HTLC and HT-UHPLC 4.4 Advantage of high temperature in life science analysis 4.5 HT-UHPLC in comprehensive on-line two-dimensional liquid chromatography (LC x LC) 4.6 Conclusion 5. Comparison of the performance of totally porous and core-shell particles 5.1. Introduction 5.2. Column performance 5.3. Possibilities of recent core-shell technology 5.4. Particle size distribution and roughness of core-shell particles 5.5. Loading capacity of core-shell particles 5.6. Limited efficiency when core-shell particles packed in narrow-bore columns 5.7. Extra column effects, contribution to band broadening 5.8. Performance of core-shell and totally porous particles in isocratic elution mode 5.9. Performance of core-shell and totally porous particles in gradient elution mode 5.10. Conclusion 6.1 Introduction 6.2 Analytical Conditions for performing HILIC. 6.3 Applications of HILIC in UHPLC. 6.4 References. 7.1 Introduction 7.2 Selection of ionization techniques 7.3 Overview of mass analyzers and their main features 7.4 New developments in mass spectrometry applicable in UHPLC/MS 7.5 Conclusions 8.1 Introduction 8.2 Solubility 8.3 Ionization 8.4 Lipophilicity 8.5 Permeability 8.6 Conclusion 8.7 References 9.1 Introduction 9.2 UHPLC in Bioanalysis 9.3 Sample preparation for UHPLC in bioanalysis 9.4 Conclusions 10.1 Introduction 10.2 GC-MS Analyses 10.3 LC-MS(/MS) Analyses 10.4 Application of UHPLC-MS(/MS) for Drug Testing in Sports 10.5 Conclusion References 11.1 Introduction 11.2 Use of UHPLC for the Analysis of Seized Drugs 12.1. Pharmaceuticals as environmental contaminants 12.2. Analysis of pharmaceuticals in environmental samples 12.3. Occurrence of pharmaceuticals in environmental and wastewater samples 12.4. Conclusions Acknowledgements References 13.1 Introduction 13.2 Multiple Facets of UHPLC in NP research 13.3 Fast Targeted Analysis 13.4 Fast Non-Targeted Analysis, Fingerprinting, and Metabolomics 13.5 High-Resolution Profiling and Metabolite ID 13.6 Conclusion Acknowledgments References 14.1. Introduction 14.2. Pre-analysis Considerations: Protocol Design, Sample Collection, Storage and Preparation 14.3. Sample Preparation for Serum and/Plasma 14.4. Collection and Storage of Urine Samples 14.5. UHPLC-MS-Based Metabolite Profiling 14.6. Applications of UHPLC-MS to Human Metabolic Profiling Studies 14.7 Current Challenges for UHPLC-MS in Global metabolic profiling Studies 14.8. Conclusions
Es gelten unsere Allgemeinen Geschäftsbedingungen: www.buecher.de/agb
Impressum
www.buecher.de ist ein Internetauftritt der buecher.de internetstores GmbH
Geschäftsführung: Monica Sawhney | Roland Kölbl | Günter Hilger
Sitz der Gesellschaft: Batheyer Straße 115 - 117, 58099 Hagen
Postanschrift: Bürgermeister-Wegele-Str. 12, 86167 Augsburg
Amtsgericht Hagen HRB 13257
Steuernummer: 321/5800/1497
USt-IdNr: DE450055826