43,95 €
43,95 €
inkl. MwSt.
Sofort per Download lieferbar
payback
22 °P sammeln
43,95 €
43,95 €
inkl. MwSt.
Sofort per Download lieferbar

Alle Infos zum eBook verschenken
payback
22 °P sammeln
Als Download kaufen
43,95 €
inkl. MwSt.
Sofort per Download lieferbar
payback
22 °P sammeln
Jetzt verschenken
43,95 €
inkl. MwSt.
Sofort per Download lieferbar

Alle Infos zum eBook verschenken
payback
22 °P sammeln
  • Format: PDF

Clean and process water tests for aeration efficiency measurements were performed on a suite of diffusers in different processes for approximately one year. The research plan was set up to test the same diffusers in different processes and different diffusers in the same process. The most evident finding regarding the scaling factor for oxygen transfer efficiency in process water (factor) is that all diffusers seems to experience a decrease with time until reaching what appears a stabilization value. As time progressed, the diffuser performance decreased for all diffusers also in terms of…mehr

  • Geräte: PC
  • mit Kopierschutz
  • eBook Hilfe
  • Größe: 5.6MB
  • FamilySharing(5)
Produktbeschreibung
Clean and process water tests for aeration efficiency measurements were performed on a suite of diffusers in different processes for approximately one year. The research plan was set up to test the same diffusers in different processes and different diffusers in the same process. The most evident finding regarding the scaling factor for oxygen transfer efficiency in process water (factor) is that all diffusers seems to experience a decrease with time until reaching what appears a stabilization value. As time progressed, the diffuser performance decreased for all diffusers also in terms of diffuser head loss (or dynamic wet pressure DWP). At the same time, it was observed that once the diffuser have been colonized a relatively stable base/plateau of microbial species remains in the diffuser surface. Regarding the DNA concentration found on the membranes, the silicone membrane tube was the less fouled than the other membrane tubes. Although tested in different processes, the relative microbial abundance on the membrane diffusers was of the same magnitude. One should expect much higher fouling for the high-rate process, however this may be more pronounced as the fouling biofilm fully ripens, possibly after the first year of operation.

Dieser Download kann aus rechtlichen Gründen nur mit Rechnungsadresse in A, B, BG, CY, CZ, D, DK, EW, E, FIN, F, GR, HR, H, IRL, I, LT, L, LR, M, NL, PL, P, R, S, SLO, SK ausgeliefert werden.